PDF of this product
Additional Product Information
pdf Datacal Software (485 Kb)

AOIP TM 6602 / 6612 / 6630 Thermometers

User friendly and robust, these tools have been designed to simplify temperature transmitters and probes maintenance and commissioning.

    Features

  • High accurate temperature measurement at 0.02 % RDG
  • Protected for on-site use
  • Easy connection system
  • Protected for on-site use
  • Metrological and control tool
Description

User friendly, robust, these tools have been designed to simplify temperature transmitters and probes maintenance and commissioning. They measure and generate in thermocouple or RTD's.

Advanced features
  • Well adapted for different process job procedures thanks to their ranges and specific functions such scaling, ramping,...
  • High accuracy: 0,02% of reading
  • Very low temperature coefficient: 10 ppm /degree C in thermocouples and 7 ppm/degree C in resistance even in bad outside environmental conditions accuracies are not modified
  • Measurement and simulation of 14 thermocouples and 12 RTD types

    Functionalities TC 6602
  • Measured quantity: Thermocouples
  • Low temperature coefficient: 10 ppm/degree C
  • High accuracy 0.02% RDG
  • Large backlight display: MIN, MAX and AVERAGE value
  • Communication modes: USB
  • Additional functions:
    Scaling
    Memory and direct reading as curves and list of values
    Calibrated sensor Database
    HOLD function

    Functionalities TC 6612
  • Measured quantity: RTDs
  • Low temperature coefficient: 7 ppm/degree C
  • High accuracy: 0.02% RDG IN
  • Large backlight display: MIN, MAX and AVERAGE value
  • Communication modes: USB
  • Additional functions:
    Scaling
    Memory and direct reading as curves and list of values
    Calibrated sensor Database
    HOLD function

    Functionalities TC 6630
  • Measured quantity: Thermocouples and RTDs
  • Low temperature coefficient: 10 ppm/degree C in thermocouples, 7 ppm/degree C in RTDs
  • High accuracy: 0.02% RDG IN
  • Large backlight display: MIN, MAX and AVERAGE value
  • Communication modes: USB
  • Additional functions:
    Scaling
    Memory and direct reading as curves and list of values
    Calibrated sensor Database
    HOLD function

    DATACAL Calibration management software (21 CFR Part 11)
  • 100% paperless calibration procedures!
  • Full configuration of instruments
  • Real time processing of data
  • Issue your own customized calibration certificates
  • Additional pictures

    Connexion of RTD

    Connexion of thermocouples

    Datacal

    TC6621_22

    Instruments Techno Test inc.

    Instruments Techno Test inc.
    2345, Michelin street, #100
    Laval, Qc
    H7L 5B9

    Téléphone : (450) 681-5777
    Télécopieur : (450) 681-3773

    Printed from: catalogue.techno-test.com/products/1-Test___Measurement/194-Micro_Ohmmeter___Thermometer/470-AOIPTM6602_6612_6630-AOIP_TM_6602___6612___6630_Thermometers.html